Shipping information


 Shipping costs are based on the total weight and value of your order. Minimum shipping is $15. Time of delivery is based on your location.

For all international orders, please contact airah@airah.org.au with your request.

Products

 
Skip to search results
Data pager
Data pager
12
Page size:
PageSizeComboBox
select
 33 items in 2 pages
Show all 33
 
Data pager
Data pager
12
Page size:
PageSizeComboBox
select
 33 items in 2 pages
Show all 33
Additional Image
The HVAC&R Search Compendium is the leading reference of companies working in Australia’s heating, ventilation, air conditioning and refrigeration sector. It is designed to highlight the key companies in the HVAC&R industry: their stories, their offerings, and their contact details. It complements the digital marketplace, www.hvacrsearch.com.au, and replaces AIRAH’s Industry Directory publication.

Published:... Details
Additional Image
Backflow Inspection Booklet - triplicate copies x 25.

AIRAH members receive a discount on this product when they log in.
Additional Image
Backflow tags are used to show that the backflow device it is attached to must be tested and maintained every 12 months.

AIRAH members receive a discount on this product when they log in.
Additional Image
DA02 comprehensively covers the fundamentals of noise control, terminology and definitions, the use and calculations of noise ratings and recommended design criteria. It also describes design methods for analysing sound transmission from noise sources, both inside and outside buildings in order to estimate interior and exterior noise levels.

The first part – fundamentals, noise ratings and criteria – includes the following five sections: 1. Introduction, 2.... Details
Additional Image
DA03 features detailed guidelines for designing air conditioning ductwork systems.

This manual includes the following 13 sections: 1. Introduction, 2. Design consideration, 3. Fundamentals and terminology, 4. Procedure for designing ductwork systems, 5. Duct layout and sizing, 6. Duct fitting pressure loss data, 7. The fan duty and system effect, 8. Duct heat and leakage losses or gains, 9. Noise in the ductwork system - general considerations, 10. Acoustically analysing... Details
Additional Image
DA07 Criteria for Moisture Control Design Analysis in Buildings is a technical resource that helps specify performance-based design criteria for predicting, mitigating, or reducing moisture damage to the building envelope, materials, components, systems, and furnishings, depending on climate, construction type, and HVAC system operation. This includes: a) Criteria for selecting analytic procedures; b) Criteria for inputs; c) Criteria for evaluation and use of outputs. It is designed... Details
Additional Image
DA08 is a concise overview of air conditioning systems, describing the different systems and system components for the full range of equipment used by the air conditioning, heating and ventilation industry in Australia.

This manual is a must for newcomers to the industry and is comprised of the following five sections: 1. Introduction, 2. Components of refrigeration and air conditioning systems, 3. Commercial and industrial air conditioning systems, 4. Air conditioning... Details
Additional Image
DA09 is a comprehensive technical manual describing ways to estimate air conditioning loads and associated psychrometrics. It includes monthly ambient dry and wet bulb design conditions for over 500 locations in Australia and various locations in New Guinea, New Zealand and South East Asia.

This manual contains the following nine sections: 1. Survey and load estimate, 2. Design conditions, 3. Heat storage, 4. Solar heat gain-glass, 5. Heat and moisture flow, 6.... Details
Additional Image
DA11 is a detailed guideline for the design of steam distribution and condensate recovery systems. This manual describes precisely how to design and install efficient reticulation systems to maximise steam heat energy and minimise waste.

The following five sections are included: 1. Introduction, 2. Steam distribution, 3. Steam trapping, 4. Condensate recovery and 5. Flash steam.

Published: 1998 | Pages: 50

AIRAH members receive a discount on this... Details
Additional Image
DA12 Energy Efficiency in Cold Rooms is the definitive reference for walk-in cold room energy efficiency in Australia. Using DA12 will help all stakeholders overcome the barriers to improved energy efficiency in cold room operation. It is designed for engineers, refrigeration technicians and contractors, as well as equipment owners, operators and specifiers.

This manual includes the following sections: 1. Scope and introduction, 2. Design considerations, 3. Star rating... Details
Additional Image
DA13 is a comprehensive guideline on the selection and application of centrifugal and axial fans for mechanical services in buildings.

This manual includes the following 11 sections: 1. Introduction, 2. Fan types and their characteristics, 3. Pressure and its measurement, 4. Fan ratings, 5. Fan and systems resistance laws, 6. Fan control, 7. Series and parallel operation, 8. Noise from fan systems, 9. Essentials of a fan enquiry, 10. Fan and system interaction, and 11.... Details
Additional Image
DA15 focuses on the selection and application of filters for air conditioning and ventilation.

The manual includes the following sections: 1. Introduction, 2. Theory of filtration, 3. Air filter performance characteristics, 4. Testing methods, 5. Types of air filters and 6. Filter selection and installation, including application guidelines for the full range of buildings in which filters are used.

Published: 2019 | Pages: 152

AIRAH members... Details
Additional Image
DA16 provides advice on the design of the various types of configurations of piping systems and the method for designing such piping systems.

The 135-page manual includes the following nine sections: 1. Introduction, 2. Design considerations, 3. Calculation of pressure loss, 4. Control valve selection, 5. Heat gains and losses, 6. Other considerations, 7. Example calculations, 8. Pipe expansion and pipe stress analysis and 9. Estimating the cost of a piping system. It... Details
Additional Image
DA17 is a state of the art guide to the selection and application of cooling towers for mechanical services in buildings. The scope of this application manual includes the manufacture, design, installation, maintenance and management of cooling towers and their associated systems. This manual contains detailed advice and information on open and closed circuit, direct and indirect cooling towers.

DA17 includes the following seven sections: 1. Introduction, 2. Tower design... Details
Additional Image
DA18 provides details of the scientific principles on which present practices of water treatment are based. Describes proven techniques which can reasonably be expected to be applied in water treatment system design, installation maintenance and monitoring.

This manual includes the following 22 sections: 1. Introduction, 2. Water chemistry, 3. Parameters affecting water quality, 4. Scale control principles, 5. Principles of corrosion prevention, 6. Inhibitors for... Details
Additional Image
The hard copy of DA19 may be purchased at the AIRAH member rate ($110 regular) or non-member rate ($440). Non-members can combine their DA19 order with an AIRAH membership at $460 + Postage.

AIRAH members also receive exclusive, free access to the online edition of DA19. Members can log in to their accounts to download this resource.

Now in its fourth edition, DA19 has been the definitive reference for HVAC&R maintenance in Australia for more than 20... Details
Additional Image
The new hard copy edition of DA19 HVAC&R Maintenance have been released in October 2019. AIRAH is offering a package containing a DA19 hard copy and a one-year AIRAH membership at the Affiliate level.

Purchase of this package will also provide free online access to a range of AIRAH’s DA manuals – including the 2019 edition of DA19. This is an exclusive AIRAH member benefit.

About DA19: DA19 HVAC&R Maintenance is used throughout the... Details
Additional Image
DA20 is essential to anyone designing for humid tropical environments. It is intended for use as a guide to designers in the preparation of plans and specifications and for suppliers, installers, commissioning and maintenance personnel in the application of air conditioning in moist tropical climates.

DA20 includes the following seven sections: 1. Introduction, 2. Climate and design conditions, 3. Heat and moisture flow, 4. Building considerations, 5. System design, 6.... Details
Additional Image
DA21 contains all the very latest information and recognised best practices, for all types of ammonia systems. The manual covers the selection of ammonia as a refrigerant, giving examples of traditional areas where ammonia is used as the primary refrigerant.

DA21 is comprised of the following 14 sections: 1. Introduction, 2. Refrigerant selection, 3. Heat load calculation, product cooling and storage, 4. System selection, 5. Plant room equipment, 6. Production area... Details
Additional Image
This manual includes invaluable advice for those involved in the day to day task of commissioning air conditioning systems and equipment. The procedures involved in preparing and commissioning water systems are discussed in the context of achieving the designer's intent and ensuring that systems operate at maximum efficiency.

DA24 is comprised of 68 pages which cover the following contents: 1. Introduction, 2. Commissioning overview, 3. Some fundamentals, 4. Flow... Details
Additional Image
This manual takes a close-up look at measures to remediate indoor air quality issues that can usually be implemented without major redesign or system modification. These measures are presented in the form of suggested policies, procedures, and maintenance / operational practices to help provide acceptable indoor air quality in systems that are capable of appropriate performance. Recommendations are also provided for dealing with complaint situations.

DA26 includes the... Details
Additional Image
DA27 helps define and standardise the commissioning process, outline the critical steps and promote a common language.


The manual is comprised of the following nine sections: 1. Scope and introduction, 2. Commissioning overview, 3. The commissioning process, 4. Specifying and procuring commissioning, 5. Key commissioning documentation, 6. Testing and commissioning, 7. System specific documentation requirements, 8. Transition to operation and 9.... Details
Additional Image
This application manual is intended to help building practitioners understand and manage BMCS and building controls. It outlines a generic process for the design and implementation of control systems for buildings.


This manual includes the following ten chapters: 1. Scope and introduction, 2. Controls - an overview, 3. Building management and control systems (BMCS), 4. Intelligent buildings, 5. Implementing a control system, 6. Briefing, scoping and engaging, 7.... Details
Additional Image
If you are looking for information on how to specify or design low energy, water efficient, reliable, low impact, sustainable cooling systems then this application manual may be just what you need. Written in plain English, this manual provides essential information for the purchaser, designer, installer, owner, operator and maintainer of any evaporative air cooling system. It outlines best practices for the selection, application and operation of evaporative air cooling systems.... Details
Additional Image
This is an industry guide on managing the health and safety risks associated with the safe design, manufacture, supply, installation, conversion, commissioning, operation, maintenance, decommissioning, dismantling and disposal of refrigeration and air conditioning equipment and systems that use a flammable refrigerant. This industry guide is required because of the increasing demand for flammable refrigerants due to their low-GWP characteristics. Hydrocarbon refrigerants are broadly... Details