Shipping information


Shipping costs are based on the total weight and value of your order. Minimum shipping is $15. Time of delivery is based on your location.

For all international orders, please contact [email protected] with your request. 

Products

Add
Skip to search results
Data pager
Data pager
123
Page size:
 52 items in 3 pages
Show all 52
 
Data pager
Data pager
123
Page size:
 52 items in 3 pages
Show all 52
A3 Psychrometric Pads
The A3-sized AIRAH psychrometric pad features 45 pages of tear away psychrometric charts.


AIRAH members receive discounts on all product prices when they log in.
A4 Psychrometric Pads
The A4-sized AIRAH Psychrometric pad features 50 pages of tear-away psychrometic charts.

AIRAH members receive discounts on all product prices when they log in.
AIRAH Technical Handbook (hard copy)
The AIRAH Technical Handbook is the definitive technical reference for HVAC&R practitioners, covering design fundamentals, look up charts, equations, engineering properties and more.

Sixth edition AIRAH Technical Handbook hard copy pricing:

Member: $149
Non-member: $574 (save $35 on a one-year Affiliate membership)*

* The purchase of the AIRAH Technical Handbook by a non-member is packaged with a one-year AIRAH... Details
Product Icon
AIRAH WEBSITE
Australian Refrigeration & Airconditioning Volume 1
Australian Refrigeration and Air-Conditioning Volume 1.

For more information on this resource, please click here.
Australian Refrigeration & Airconditioning Volume 2
Australian Refrigeration and Air-Conditioning Volume 2.

For more information on this resource, please click here.
Backflow Inspection Booklets
Backflow Inspection Booklet - triplicate copies x 25.


AIRAH members receive a discount on this product when they log in.
Backflow Tags
Backflow tags are used to show that the backflow device it is attached to must be tested and maintained every 12 months.


AIRAH members receive a discount on this product when they log in.
Complete set of DA manuals
Purchase a complete set of AIRAH's DA manuals and take advantage of our discounted bundle pricing. Typical individual DA manual pricing is $79–$110 (AIRAH members) or $229–$440 (non-members).

The set includes all of AIRAH's DA manuals: DA01 Centrifugal Pumps; DA02 Noise Control; DA03 Ductwork for Air Conditioning; DA04 Air System Balancing – in HVAC; DA05 Guide to Fire and Smoke Control in Buildings using AS 1668 Part 1; DA06 Guide to Fire, Smoke and Air Dampers using AS... Details
DA bundle deal - DA04 and DA24
AIRAH has released two new/updated Design Application (DA) manuals: DA04 Air System Balancing – in HVAC and DA24 Hydronic System Balancing – in HVAC.

DA04 discusses the... Details
DA bundle deal - DA05 and DA06
AIRAH has released two new Design Application (DA) manuals: DA05 Guide to Fire and Smoke Control in Buildings using AS 1668 Part 1 and DA06 Guide to Fire, Smoke and Air Dampers using AS 1682 Parts 1 & 2.

DA05 provides a holistic overview of smoke control in buildings, as applied by Australian Standard AS... Details
DA01 Centrifugal Pumps
DA01 is a guideline for the selection and application of centrifugal pumps used in the building services industry for pumping water and other fluids.


This manual includes the following sections: 1. Scope and introduction, 2. Centrifugal pumps, an overview, 3. Centrifugal pumps and energy use, 4. Pump performance, 5. Pump and system design, 6. Pump selection, 7. Controlling pumps, 8. System configuration, 9. Installation and commissioning, and 10. Operation and... Details
DA02 Noise Control
DA02 comprehensively covers the fundamentals of noise control, terminology and definitions, the use and calculations of noise ratings and recommended design criteria. It also describes design methods for analysing sound transmission from noise sources, both inside and outside buildings in order to estimate interior and exterior noise levels.

The first part – fundamentals, noise ratings and criteria – includes the following five sections: 1. Introduction, 2. Fundamentals,... Details
DA03 Ductwork for Air Conditioning
DA03 features detailed guidelines for designing air conditioning ductwork systems.

This manual includes the following 13 sections: 1. Introduction, 2. Design consideration, 3. Fundamentals and terminology, 4. Procedure for designing ductwork systems, 5. Duct layout and sizing, 6. Duct fitting pressure loss data, 7. The fan duty and system effect, 8. Duct heat and leakage losses or gains, 9. Noise in the ductwork system - general considerations, 10. Acoustically analysing... Details
DA04 Air System Balancing – in HVAC
DA04 Air System Balancing – in HVAC is a new Design Application (DA) manual in AIRAH’s collection of technical resources.

This DA manual discusses the testing, adjusting and balancing (TAB) of air distribution systems in heating, ventilation, air conditioning and refrigeration (HVAC&R) applications. It includes the following sections: 1. Scope and introduction, 2. Commissioning and TAB – an overview, 3. Fundamentals of airflow in ducts, 4. Measuring airflow, 5.... Details
DA05 Guide to Fire and Smoke Control in Buildings
DA05 Guide to Fire and Smoke Control in Buildings using AS 1668 Part 1 is a new Design Application (DA) manual in AIRAH’s collection of technical resources.

The manual covers fire and smoke control in buildings. It is the guide to using and applying AS 1668.1-2015 The use of ventilation and air conditioning in buildings. Part 1: Fire and smoke control in buildings.

You can save on your hard copy order of DA05 when you bundle it with Details
DA06 Guide to Fire, Smoke and Air Dampers
DA06 Guide to Fire, Smoke and Air Dampers using AS 1682 Parts 1 & 2 provides a complete overview of the application of fire, smoke, and air dampers in building mechanical ventilation and HVAC.

It promotes the correct selection, installation, and commissioning of fire, smoke, and (smoke exhaust) air dampers within the HVAC industry and associated trades.

You can save on your hard copy order of DA06 when you bundle it with Details
DA07 Criteria for Moisture Control Design Analysis
DA07 Criteria for Moisture Control Design Analysis in Buildings is a technical resource that helps specify performance-based design criteria for predicting, mitigating, or reducing moisture damage to the building envelope, materials, components, systems, and furnishings, depending on climate, construction type, and HVAC system operation. This includes: a) Criteria for selecting analytic procedures; b) Criteria for inputs; c) Criteria for evaluation and use of outputs. It is designed... Details
DA08 HVAC&R an introduction
DA08 is a concise overview of air conditioning systems, describing the different systems and system components for the full range of equipment used by the air conditioning, heating and ventilation industry in Australia.

This manual is a must for newcomers to the industry and is comprised of the following five sections: 1. Introduction, 2. Components of refrigeration and air conditioning systems, 3. Commercial and industrial air conditioning systems, 4. Air conditioning... Details
DA09 Air Conditioning Load Estimation and Psychrometrics
This is the fourth edition of the AIRAH air conditioning load estimation manual. The manual provides a range of information and design data that can be used in any load estimation calculation.

The method outlined in this edition continues to follow the principles of the Carrier Method of load estimation, originally developed by the Carrier Corporation prior to 1972, but has incorporated several modifications not included in the original version.

This manual ... Details
DA11 Steam and Condensate
DA11 is a detailed guideline for the design of steam distribution and condensate recovery systems. This manual describes precisely how to design and install efficient reticulation systems to maximise steam heat energy and minimise waste.

The following five sections are included: 1. Introduction, 2. Steam distribution, 3. Steam trapping, 4. Condensate recovery and 5. Flash steam.

Published: 1998 | Pages: 50

AIRAH members receive a discount on this... Details
DA12 Energy Efficiency in Cold Rooms
DA12 Energy Efficiency in Cold Rooms is the definitive reference for walk-in cold room energy efficiency in Australia. Using DA12 will help all stakeholders overcome the barriers to improved energy efficiency in cold room operation. It is designed for engineers, refrigeration technicians and contractors, as well as equipment owners, operators and specifiers.

This manual includes the following sections: 1. Scope and introduction, 2. Design considerations, 3. Star rating... Details
DA13 Fans
DA13 is a comprehensive guideline on the selection and application of centrifugal and axial fans for mechanical services in buildings.

This manual includes the following 11 sections: 1. Introduction, 2. Fan types and their characteristics, 3. Pressure and its measurement, 4. Fan ratings, 5. Fan and systems resistance laws, 6. Fan control, 7. Series and parallel operation, 8. Noise from fan systems, 9. Essentials of a fan enquiry, 10. Fan and system interaction, and 11.... Details
DA15 Air Filters and Cleaning Devices
DA15 focuses on the selection and application of filters for air conditioning and ventilation.

The manual includes the following sections: 1. Introduction, 2. Theory of filtration, 3. Air filter performance characteristics, 4. Testing methods, 5. Types of air filters and 6. Filter selection and installation, including application guidelines for the full range of buildings in which filters are used.

Published: 2019 | Pages: 152

AIRAH members receive... Details
DA16 Air Conditioning Water Piping
DA16 provides advice on the design of the various types of configurations of piping systems and the method for designing such piping systems.

The 135-page manual includes the following nine sections: 1. Introduction, 2. Design considerations, 3. Calculation of pressure loss, 4. Control valve selection, 5. Heat gains and losses, 6. Other considerations, 7. Example calculations, 8. Pipe expansion and pipe stress analysis and 9. Estimating the cost of a piping system. It... Details