Backflow Inspection Booklet - triplicate copies x 25.

AIRAH members receive a discount on this product when they log in.
Additional Image
Backflow tags are used to show that the backflow device it is attached to must be tested and maintained every 12 months.

AIRAH members receive a discount on this product when they log in.
Additional Image
DA01 is a guideline for the selection and application of centrifugal pumps used in the building services industry for pumping water and other fluids. This manual includes the following sections: 1. Scope and introduction, 2. Centrifugal pumps, an overview, 3. Centrifugal pumps and energy use, 4. Pump performance, 5. Pump and system design, 6. Pump selection, 7. Controlling pumps, 8. System configuration, 9. Installation and commissioning, and 10. Operation and maintenance. Number of... Details
Additional Image
DA02 comprehensively covers the fundamentals of noise control, terminology and definitions, the use and calculations of noise ratings and recommended design criteria. It also describes design methods for analysing sound transmission from noise sources, both inside and outside buildings in order to estimate interior and exterior noise levels. The first part - Fundamentals, noise ratings and criteria includes the following five sections: 1. Introduction, 2. Fundamentals, terminology... Details
Additional Image
DA03 features detailed guidelines for designing air conditioning ductwork systems. This manual includes the following 13 sections: 1. Introduction, 2. Design consideration, 3. Fundamentals and terminology, 4. Procedure for designing ductwork systems, 5. Duct layout and sizing, 6. Duct fitting pressure loss data, 7. The fan duty and system effect, 8. Duct heat and leakage losses or gains, 9. Noise in the ductwork system - general considerations, 10. Acoustically analysing a duct... Details
Additional Image
DA08 is a concise overview of air conditioning systems, describing the different systems and system components for the full range of equipment used by the air conditioning, heating and ventilation industry in Australia. This manual is a must for newcomers to the industry and is comprised of the following five sections: 1. Introduction, 2. Components of refrigeration and air conditioning systems, 3. Commercial and industrial air conditioning systems, 4. Air conditioning systems and 5. ... Details
Additional Image
DA09 is a comprehensive technical manual describing ways to estimate air conditioning loads and associated psychrometrics. It includes monthly ambient dry and wet bulb design conditions for over 500 locations in Australia and various locations in New Guinea, New Zealand and South East Asia. This manual contains the following nine sections: 1. Survey and load estimate, 2. Design conditions, 3. Heat storage, 4. Solar heat gain-glass, 5. Heat and moisture flow, 6. Infiltration and... Details
Additional Image
DA11 is a detailed guideline for the design of steam distribution and condensate recovery systems. This manual describes precisely how to design and install efficient reticulation systems to maximise steam heat energy and minimise waste. The following five sections are included: 1. Introduction, 2. Steam distribution, 3. Steam trapping, 4. Condensate recovery and 5. Flash steam.

AIRAH members receive a discount on this product when they log in.
Additional Image
DA13 is a comprehensive guideline on the selection and application of centrifugal and axial fans for mechanical services in buildings. This manual includes the following 11 sections: 1. Introduction, 2. Fan types and their characteristics, 3. Pressure and its measurement, 4. Fan ratings, 5. Fan and systems resistance laws, 6. Fan control, 7. Series and parallel operation, 8. Noise from fan systems, 9. Essentials of a fan enquiry, 10. Fan and system interaction, and 11. Effects of fan ... Details
Additional Image
DA15 is a fact filled publication on the selection and application of filters for air conditioning and ventilation. This manual includes the following six sections: 1. Introduction, 2. Theory of filtration, 3. Air filter performance characteristics, 4. Testing methods, 5. Types of air filters and 6. Filter selection and installation, including application guidelines for the full range of buildings in which filters are used. Number of pages: 37.

AIRAH members receive a... Details
Additional Image
DA16 provides advice on the design of the various types of configurations of piping systems and the method for designing such piping systems. The 135-page manual includes the following nine sections: 1. Introduction, 2. Design considerations, 3. Calculation of pressure loss, 4. Control valve selection, 5. Heat gains and losses, 6. Other considerations, 7. Example calculations, 8. Pipe expansion and pipe stress analysis and 9. Estimating the cost of a piping system. It also includes... Details
Additional Image
DA17 is a state of the art guide to the selection and application of cooling towers for mechanical services in buildings. The scope of this application manual includes the manufacture, design, installation, maintenance and management of cooling towers and their associated systems. This manual contains detailed advice and information on open and closed circuit, direct and indirect cooling towers. DA17 includes the following seven sections: 1. Introduction, 2. Tower design and... Details
Additional Image
DA18 provides details of the scientific principles on which present practices of water treatment are based. Describes proven techniques which can reasonably be expected to be applied in water treatment system design, installation maintenance and monitoring. This manual includes the following 22 sections: 1. Introduction, 2. Water chemistry, 3. Parameters affecting water quality, 4. Scale control principles, 5. Principles of corrosion prevention, 6. Inhibitors for corrosion control,... Details
Additional Image
This manual covers maintenance for all components of HVAC&R systems while performance testing covers the performance capacity of individual items of equipment, power consumption monitoring and energy savings. Contract documentation covers the basic documentation required in maintenance including computer programs and their application. The maintenance discussed in this manual can be applied to achieve a variety of objectives including: health and safety, comfort, indoor air quality,... Details
Additional Image
DA20 is essential to anyone designing for humid tropical environments. It is intended for use as a guide to designers in the preparation of plans and specifications and for suppliers, installers, commissioning and maintenance personnel in the application of air conditioning in moist tropical climates. DA20 includes the following seven sections: 1. Introduction, 2. Climate and design conditions, 3. Heat and moisture flow, 4. Building considerations, 5. System design, 6. Equipment... Details
Additional Image
DA21 contains all the very latest information and recognised best practices, for all types of ammonia systems. The manual covers the selection of ammonia as a refrigerant, giving examples of traditional areas where ammonia is used as the primary refrigerant. DA21 is comprised of the following 14 sections: 1. Introduction, 2. Refrigerant selection, 3. Heat load calculation, product cooling and storage, 4. System selection, 5. Plant room equipment, 6. Production area equipment, 7.... Details
Additional Image
This manual includes invaluable advice for those involved in the day to day task of commissioning air conditioning systems and equipment. The procedures involved in preparing and commissioning water systems are discussed in the context of achieving the designer's intent and ensuring that systems operate at maximum efficiency. DA24 is comprised of 68 pages which cover the following contents: 1. Introduction, 2. Commissioning overview, 3. Some fundamentals, 4. Flow measurement and... Details
Additional Image
This manual takes a close-up look at measures to remediate indoor air quality issues that can usually be implemented without major redesign or system modification. These measures are presented in the form of suggested policies, procedures, and maintenance / operational practices to help provide acceptable indoor air quality in systems that are capable of appropriate performance. Recommendations are also provided for dealing with complaint situations. DA26 includes the following ten... Details
Additional Image
DA27 helps define and standardise the commissioning process, outline the critical steps and promote a common language. The manual is comprised of the following nine sections: 1. Scope and introduction, 2. Commissioning overview, 3. The commissioning process, 4. Specifying and procuring commissioning, 5. Key commissioning documentation, 6. Testing and commissioning, 7. System specific documentation requirements, 8. Transition to operation and 9. Retrocommissioning. Also included are... Details
Additional Image
This application manual is intended to help building practitioners understand and manage BMCS and building controls. It outlines a generic process for the design and implementation of control systems for buildings. This manual includes the following ten chapters: 1. Scope and introduction, 2. Controls - an overview, 3. Building management and control systems (BMCS), 4. Intelligent buildings, 5. Implementing a control system, 6. Briefing, scoping and engaging, 7. System design and... Details
Additional Image
If you are looking for information on how to specify or design low energy, water efficient, reliable, low impact, sustainable cooling systems then this application manual may be just what you need. Written in plain English, this manual provides essential information for the purchaser, designer, installer, owner, operator and maintainer of any evaporative air cooling system. It outlines best practices for the selection, application and operation of evaporative air cooling systems.... Details
Additional Image
Purchase the complete set of AIRAH's DA Manuals and receive a 10% discount. The set includes all 19 AIRAH DA manuals: DA01 Centrifugal Pumps, DA02 Noise Control, DA03 Ductwork for Air Conditioning, DA08 HVAC&R - An introduction, DA09 Air Conditioning Load Estimation, DA11 Steam and Condensate, DA13 Fans, DA15 Air Filters, DA16 Air Conditioning Water Piping, DA17 Cooling Towers, DA18 Water Treatment, DA19 HVAC&R Maintenance, DA20 Humid Tropical Air Conditioning, DA21 Ammonia... Details
Additional Image
These are 17 presentations from The Future of HVAC Conference 2016. Over nine hours of presentation, slides and panel discussion you can view and listen to at your leisure, with topics exploring advances in the design process, HVAC and smart grids, net-zero buildings, Big Data, and many others.

AIRAH members receive a discount on this product when they log in.
Additional Image
This is an industry guide on managing the health and safety risks associated with the safe design, manufacture, supply, installation, conversion, commissioning, operation, maintenance, decommissioning, dismantling and disposal of refrigeration and air conditioning equipment and systems that use a flammable refrigerant. This industry guide is required because of the increasing demand for flammable refrigerants due to their low-GWP characteristics. Hydrocarbon refrigerants are broadly... Details
Additional Image
The HVAC Hygiene Best Practice Guideline establishes the criteria for evaluating the internal cleanliness of HVAC system components; clearly determines when cleaning is required, according to the building use; describes the components of HVAC systems to be evaluated; the types of contamination likely to be encountered and includes for post fire and flood damage assessments; minimum inspection frequencies for various HVAC systems and components are specified for scheduled maintenance... Details